Nosivi sistemi za procjenu kinematike ramena: sistematski pregled.
BMC musculoskeletal disorders
Sažetak istraživanja
Pozadina Nosivi senzori dobijaju sve veći uticaj u dijagnostičkom i rehabilitacionom polju za procenu motoričkih sposobnosti osoba sa neurološkim ili mišićno-koštanim oštećenjima.
Cilj ovog sistematskog pregleda literature je da se analiziraju nosivi sistemi za praćenje kinematike ramena i njihova primenjivost u kliničkim uslovima i rehabilitaciji.
Metode Izvršena je sveobuhvatna pretraga PubMed-a, Medline-a, Google Scholar-a i IEEE Xplore-a i rezultati su uključeni do jula 2019. godine. Preuzete su sve studije koje se odnose na nosive senzore za procjenu kinematike ramena.
Rezultati Uključene su sedamdeset i tri studije jer su ispunile kriterijume za uključivanje.
Rezultati su pokazali da se najčešće koriste magnetni i/ili inercijski senzori. Predloženo je da se nosivi senzori za mjerenje kinematike gornjeg ekstremiteta i/ili ramena primjenjuju kod pacijenata s različitim patološkim stanjima kao što su moždani udar, multipla skleroza, osteoartritis, puknuće rotatorne manžete. Postavljanje senzora i način pričvršćivanja bili su uglavnom heterogeni među ispitivanim studijama.
Zaključci Nosivi sistemi su obećavajuće rješenje za pružanje kvantitativnih i značajnih kliničkih informacija o napretku u rehabilitacijskom putu i za ekstrapolaciju značajnih parametara u dijagnozi patologija ramena. Postoji snažna potreba za razvojem ove nove tehnologije koja nesumnjivo služi u evaluaciji i terapiji ramena.
Prikaži originalni naslov i sažetak na engleskom
Wearable systems for shoulder kinematics assessment: a systematic review.
Background Wearable sensors are acquiring more and more influence in diagnostic and rehabilitation field to assess motor abilities of people with neurological or musculoskeletal impairments. The aim of this systematic literature review is to analyze the wearable systems for monitoring shoulder kinematics and their applicability in clinical settings and rehabilitation.
Methods A comprehensive search of PubMed, Medline, Google Scholar and IEEE Xplore was performed and results were included up to July 2019. All studies concerning wearable sensors to assess shoulder kinematics were retrieved.
Results Seventy-three studies were included because they have fulfilled the inclusion criteria. The results showed that magneto and/or inertial sensors are the most used. Wearable sensors measuring upper limb and/or shoulder kinematics have been proposed to be applied in patients with different pathological conditions such as stroke, multiple sclerosis, osteoarthritis, rotator cuff tear. Sensors placement and method of attachment were broadly heterogeneous among the examined studies.
Conclusions Wearable systems are a promising solution to provide quantitative and meaningful clinical information about progress in a rehabilitation pathway and to extrapolate meaningful parameters in the diagnosis of shoulder pathologies. There is a strong need for development of this novel technologies which undeniably serves in shoulder evaluation and therapy.
Izvorni podaci
- DOI
- 10.1186/s12891-019-2930-4
- PMID
- 31731893
- PMCID
- PMC6858749
- Provjereno
- 2026-07-26
Naslov i sažetak prevedeni su automatski i prijevod može sadržavati netačnosti ili neprecizne stručne izraze. Za sve detalje, citiranje i medicinsko tumačenje pregledajte originalnu englesku verziju članka. Ne donosite zdravstvene odluke samo na osnovu ovog prijevoda.
Pregledaj originalni članak na engleskom