Sistematski pregled / meta-analiza 2022
Probavni sistem

Procjena apendikularne mišićne mase kod sarkopenije kod starijih odraslih uz pomoć ultrazvuka: sistematski pregled i meta-analiza.

Gerontology

Bosanski prijevod

Sažetak istraživanja

Pozadina Mjerenje apendikularne mišićne mase je bitno za dijagnozu sarkopenije. Ultrazvuk je precizna i praktična metoda koja se koristi za procjenu mišićne mase.

Cilj Cilj rada bio je procijeniti dijagnostičku vrijednost ultrazvuka za apendikularnu mišićnu masu kod sarkopenije kod starijih osoba i utvrditi odgovarajuće ultrazvučne parametre.

Metode Medline, Embase, Cochrane i Web of Science baze podataka su pretražene za relevantne članke. Uključene su objavljene studije o validnosti i/ili pouzdanosti ultrazvuka za kvantifikaciju mišićne mase udova kod sarkopenije u starijoj populaciji. Sproveden je sistematski pregled na osnovu specifičnih mišića i referentnih metoda. Urađena je meta-analiza kako bi se procijenila validnost i pouzdanost ultrazvuka.

Rezultati Četrdeset članaka je uključeno u ovaj pregled. Bilo je devet, devet, devet i četiri studije uključene u kvalitativnu sintezu za dijagnostički test, koeficijent korelacije, unutarklasnu pouzdanost, odnosno međuklasnu pouzdanost. Dijagnostička vrijednost debljine rectus femoris (RF) ili gastrocnemius (GM) na ultrazvuku za sarkopeniju ili nisku mišićnu masu bila je umjerena (područje ispod zbirne krivulje radne karakteristike prijemnika [SROC] = 0,76, 95% interval pouzdanosti [CI]: 0,72-0,79, SROC: 9% 0,76-0,83, respektivno). Objedinjena korelacija između mišićne mase na dual-energetskoj rendgenskoj (DXA) ili analizi bioelektrične impedanse (BIA) i debljine mišića (MT) na ultrazvuku bila je umjerena (r = 0,56, 95% CI: 0,49-0,62). Postojala je niska do umjerena korelacija između mišićne mase na DXA ili BIA i površine poprečnog presjeka (CSA) na ultrazvuku (r = 0,267-0,584). Korelacija je bila visoka do vrlo visoka između mišićne mase iz DXA i formule predviđene ultrazvukom (r = 0,85-0,963). CSA od ultrazvuka je imao visoku ili vrlo visoku korelaciju sa onom iz kompjuterske tomografije ili magnetne rezonance (r = 0,826, koeficijent intra (inter) korelacije [ICC] = 0,998-0,999). Odgovarajuće meta-analize su pokazale dobru pouzdanost među ocjenjivačima i unutar ocjenjivača (ICC > 0,9).

Zaključak Ultrasonografija je pouzdana i validna dijagnostička metoda za kvantitativnu procjenu apendikularne mišićne mase kod sarkopenije kod starijih osoba. Čini se da su debljina i CSA RF ili GM pravi ultrazvučni parametri za predviđanje mišićne mase kod sarkopenije. Multicentrične studije sa velikim uzorcima i primena novih ultrazvučnih tehnika biće budući pravci istraživanja.

Prikaži originalni naslov i sažetak na engleskom

Evaluation of Appendicular Muscle Mass in Sarcopenia in Older Adults Using Ultrasonography: A Systematic Review and Meta-Analysis.

Background The measurement of appendicular muscle mass is essential for the diagnosis of sarcopenia. Ultrasonography is an accurate and convenient method used to evaluate muscle mass.

Objective The aim of the study was to evaluate the diagnostic value of ultrasonography for appendicular muscle mass in sarcopenia in older adults and find out proper ultrasound parameters.

Methods Medline, Embase, Cochrane, and Web of Science databases were searched for relevant articles. Published studies on the validity and/or reliability of ultrasonography for quantifying muscle mass of the limbs in sarcopenia in the older population were included. A systematic review was conducted based on specific muscles and reference methods. A meta-analysis was conducted to assess the validity and reliability of the ultrasonography.

Results Forty articles were included in this review. There were nine, nine, nine, and four studies included in the qualitative synthesis for a diagnostic test, correlation coefficient, intra-class reliability, and inter-class reliability, respectively. The diagnostic value of rectus femoris (RF) or gastrocnemius (GM) thickness on ultrasonography for sarcopenia or low muscle mass was moderate (the area under summary receiver operating characteristic curve [SROC] = 0.76, 95% confidence interval [CI]: 0.72-0.79, SROC = 0.80, 95% CI: 0.76-0.83, respectively). The pooled correlation between muscle mass on dual-energy X-ray (DXA) or bioelectrical impedance analysis (BIA) and muscle thickness (MT) on ultrasound was moderate (r = 0.56, 95% CI: 0.49-0.62). There was a low-to-moderate correlation between muscle mass on DXA or BIA and cross-sectional area (CSA) on ultrasound (r = 0.267-0.584). The correlation was high to very high between muscle mass from DXA and the ultrasound-predicted formula (r = 0.85-0.963). The CSA from ultrasound had a high or very high correlation with that from computed tomography or magnetic resonance imaging (r = 0.826, intra (inter)-correlation coefficient [ICC] = 0.998-0.999). The respective meta-analyses showed good inter-rater and intra-rater reliabilities (ICC > 0.9).

Conclusion Ultrasonography is a reliable and valid diagnostic method for the quantitative assessment of appendicular muscle mass in sarcopenia in older people. The thickness and CSA of the RF or GM seem to be proper ultrasound parameters to predict muscle mass in sarcopenia. Multicenter studies with large samples and the application of new ultrasonic techniques will be the future research directions.

Autorstvo i publikacija

Autori

Zhao R, Li X, Jiang Y, Su N, Li J, Kang L, Zhang Y, Yang M.

Časopis
Gerontology
Vrste publikacije
Meta-analiza, Istraživačka podrška vlade izvan SAD-a, Istraživački članak, Sistematski pregled, Članak u časopisu
Licenca
CC BY-NC
Citiranja u Europe PMC
55
Provjerljivi identifikatori

Izvorni podaci

DOI
10.1159/000525758
PMID
35878591
PMCID
PMC9677864
Provjereno
2026-07-26
Otvori cijeli rad u Europe PMC
Napomena o bosanskom prijevodu

Naslov i sažetak prevedeni su automatski i prijevod može sadržavati netačnosti ili neprecizne stručne izraze. Za sve detalje, citiranje i medicinsko tumačenje pregledajte originalnu englesku verziju članka. Ne donosite zdravstvene odluke samo na osnovu ovog prijevoda.

Pregledaj originalni članak na engleskom
Istraživački zapis služi za informiranje i istraživanje. Ne zamjenjuje medicinski savjet, dijagnozu ili preporuku liječenja.