Preciznost uklapanja uklonjivih okvira djelomične proteze proizvedenih pomoću CAD/CAM-a, brzog prototipa i konvencionalnih tehnika: sistematski pregled.
BioMed research international
Sažetak istraživanja
Cilj Analiza i poređenje uklapanja i tačnosti okvira pokretnih parcijalnih proteza (RPD) proizvedenih CAD/CAM i metodama brze izrade prototipa sa konvencionalnim tehnikama. Materijali i metode Ovaj sistematski pregled je sproveden prema PRISMA smjernicama. Pretraga je izvršena na PubMed/MEDLINE, Cochrane kolaboraciji, Science direct i Scopus naučnim mašinama koristeći odabrane ključne riječi MeSH. Uključeni su članci koji ispunjavaju unaprijed definirane kriterije odabira na temelju uklapanja i točnosti okvira pokretnih djelomičnih proteza (RPD) konstruiranih iz digitalnog toka rada (CAD/CAM; brza izrada prototipa) i konvencionalnih tehnika.
Rezultati Devet članaka u punom tekstu koji se sastoje od 6 in vitro i 3 in vivo studija uključeno je u ovaj pregled. Digitalni RPD-ovi su proizvedeni u svim proizvodima CAD/CAM tehnikama selektivnog laserskog sinterovanja i selektivnog laserskog topljenja. Artikli koji su koristili CAD/CAM i tehniku brzog izrade prototipa pokazali su bolje pristajanje i tačnost u poređenju sa RPD-ovima proizvedenim konvencionalnim tehnikama. Najmanje razmaka između okvira i livenog (41,677 ± 15,546 μm) pronađeno je u RPD-ovima koji su konstruirani putem digitalnih CAD/CAM sustava.
Zaključak Bolja preciznost je postignuta korištenjem CAD/CAM-a i tehnika brze izrade prototipa. RPD okviri proizvedeni pomoću CAD/CAM i tehnika brze izrade prototipa imali su klinički prihvatljivo uklapanje, superiornu preciznost i bolju tačnost od konvencionalno proizvedenih RPD okvira.
Prikaži originalni naslov i sažetak na engleskom
Fit Accuracy of Removable Partial Denture Frameworks Fabricated with CAD/CAM, Rapid Prototyping, and Conventional Techniques: A Systematic Review.
Objective Analyzing and comparing the fit and accuracy of removable partial denture (RPDs) frameworks fabricated with CAD/CAM and rapid prototyping methods with conventional techniques. Materials and methods The present systematic review was carried out according to PRISMA guidelines. The search was carried out on PubMed/MEDLINE, Cochrane collaboration, Science direct, and Scopus scientific engines using selected MeSH keywords. The articles fulfilling the predefined selection criteria based on the fit and accuracy of removable partial denture (RPD) frameworks constructed from digital workflow (CAD/CAM; rapid prototyping) and conventional techniques were included.
Results Nine full-text articles comprising 6 in vitro and 3 in vivo studies were included in this review. The digital RPDs were fabricated in all articles by CAD/CAM selective laser sintering and selective laser melting techniques. The articles that have used CAD/CAM and rapid prototyping technique demonstrated better fit and accuracy as compared to the RPDs fabricated through conventional techniques. The least gaps between the framework and cast (41.677 ± 15.546 μ m) were found in RPDs constructed through digital CAD/CAM systems.
Conclusion A better accuracy was achieved using CAD/CAM and rapid prototyping techniques. The RPD frameworks fabricated by CAD/CAM and rapid prototyping techniques had clinically acceptable fit, superior precision, and better accuracy than conventionally fabricated RPD frameworks.
Izvorni podaci
- DOI
- 10.1155/2021/3194433
- PMID
- 34532499
- PMCID
- PMC8440078
- Provjereno
- 2026-07-26
Naslov i sažetak prevedeni su automatski i prijevod može sadržavati netačnosti ili neprecizne stručne izraze. Za sve detalje, citiranje i medicinsko tumačenje pregledajte originalnu englesku verziju članka. Ne donosite zdravstvene odluke samo na osnovu ovog prijevoda.
Pregledaj originalni članak na engleskom