Sistematski pregled / meta-analiza 2019
Rak i onkologija

Mrežna meta-analiza novih i konvencionalnih tehnika biopsije sentinel limfnih čvorova kod raka dojke.

BJS open

Bosanski prijevod

Sažetak istraživanja

Pozadina

Cilj ove mrežne meta-analize bio je da se uporedi učinak plave boje same ili u kombinaciji sa radioizotopom (tehnecijum-99m, Tc) sa tri nove tehnike za detekciju sentinel limfnih čvorova kod karcinoma dojke: indocijanin zelena fluorescencija (ICG), superparamagnetski željezo-oksidni ultrazvučni oksid (SPIO) i ultrazvučni kontrastni oksid (SPIO)).

Metode PubMed, Embase, Cochrane Library, China Knowledge Research Integrated Database, ClinicalTrials.gov i OpenGrey baze podataka pretražene su do 31. novembra 2017. godine, bez ograničenja jezika. Studije koje su upoređivale performanse detekcije najmanje jedne od novih metoda (ICG, SPIO i CEUS) sa onima tradicionalnih metoda (plava boja i/ili radioizotop) uključene su u mrežnu metaanalizu.

Rezultati Uključeno je trideset pet studija. Objedinjeni omjeri rizika (RRs) za Tc (1·09, 95 posto c.i. 1·04 do 1·15), ICG (1·12, 1·07 do 1·16) i SPIO (1·09, 1·01 do 1·18) pokazali su statistički bolje performanse u detekciji samo plavog sentinela. ICG je imao najnižu stopu lažno negativnih, sa RR od 0,29 (0,16 do 0,54), zatim Tc (RR 0,44, 0,20 do 0,96) i SPIO (RR 0,45, 0,14 do 1,45), sa samo plavom bojom kao referentnom grupom.

Zaključak SPIO ili ICG sami su superiorniji od same plave boje i uporedivi sa standardnom tehnikom dvostrukog modaliteta plave boje sa Tc.

Prikaži originalni naslov i sažetak na engleskom

Network meta-analysis of novel and conventional sentinel lymph node biopsy techniques in breast cancer.

Background The aim of this network meta-analysis was to compare the performance of blue dye alone or in combination with radioisotope (technetium-99m, Tc) with three novel techniques for sentinel lymph node detection in breast cancer: indocyanine green fluorescence (ICG), superparamagnetic iron oxide (SPIO) nanoparticles and contrast-enhanced ultrasound imaging (CEUS).

Methods PubMed, Embase, the Cochrane Library, China Knowledge Research Integrated Database, ClinicalTrials.gov and OpenGrey databases were searched up to 31 November 2017, without language restriction. Studies that compared the detection performance of at least one of the novel methods (ICG, SPIO and CEUS) with that of traditional methods (blue dye and/or radioisotope) were included in network meta-analysis.

Results Thirty-five studies were included. Pooled risk ratios (RRs) for Tc (1·09, 95 per cent c.i. 1·04 to 1·15), ICG (1·12, 1·07 to 1·16) and SPIO (1·09, 1·01 to 1·18) showed statistically better performance in detecting sentinel lymph nodes than blue dye alone. ICG had the lowest false-negative rate, with a RR of 0·29 (0·16 to 0·54), followed by Tc (RR 0·44, 0·20 to 0·96) and SPIO (RR 0·45, 0·14 to 1·45), with blue dye alone as the reference group.

Conclusion SPIO or ICG alone are superior to blue dye alone and comparable to the standard dual-modality technique of blue dye with Tc.

Autorstvo i publikacija

Autori

Mok CW, Tan SM, Zheng Q, Shi L.

Časopis
BJS open
Vrste publikacije
Sistematski pregled, Pregledni članak, Mrežna meta-analiza, Članak u časopisu
Licenca
CC BY
Citiranja u Europe PMC
69
Provjerljivi identifikatori

Izvorni podaci

DOI
10.1002/bjs5.50157
PMID
31388636
PMCID
PMC6677105
Provjereno
2026-07-26
Otvori cijeli rad u Europe PMC
Napomena o bosanskom prijevodu

Naslov i sažetak prevedeni su automatski i prijevod može sadržavati netačnosti ili neprecizne stručne izraze. Za sve detalje, citiranje i medicinsko tumačenje pregledajte originalnu englesku verziju članka. Ne donosite zdravstvene odluke samo na osnovu ovog prijevoda.

Pregledaj originalni članak na engleskom
Istraživački zapis služi za informiranje i istraživanje. Ne zamjenjuje medicinski savjet, dijagnozu ili preporuku liječenja.