Sistematski pregled / meta-analiza 2018
Pluća i disanje

Dijagnostička točnost eseja izotermne amplifikacije posredovane petljom za ekstrapulmonalnu tuberkulozu: meta-analiza.

PloS one

Bosanski prijevod

Sažetak istraživanja

Pozadina Loop-posredovana izotermna amplifikacija (LAMP) koristi se za otkrivanje plućne tuberkuloze (PTB); međutim, dijagnostička tačnost LAMP testa za ekstrapulmonarnu tuberkulozu (EPTB) nije jasna. Izvršili smo meta-analizu za procjenu učinka LAMP-a u detekciji EPTB-a.

Metode Pretražili smo PubMed, EMBASE, Cochrane biblioteku, Kinesku nacionalnu infrastrukturu znanja (CNKI) i bazu podataka Wanfang za studije objavljene prije 16. septembra 2017. Pregledali smo studije i uporedili performanse LAMP-a sa performansama kompozitnog referentnog standarda (CRS) i kulture za klinički sumnjivu EPTB. Koristili smo bivarijantni model slučajnih efekata za izvođenje meta-analize i koristili smo meta-regresiju i analizu podgrupa za analizu izvora heterogenosti.

Rezultati Identifikovano je četrnaest članaka, uključujući 24 nezavisne studije (16 u poređenju LAMP sa CRS, 8 sa kulturom) EPTB. LAMP je pokazao zbirnu osjetljivost od 77% (95% interval povjerenja (CI) 68-85), specifičnost od 99% (95% CI 96-100) i površinu ispod SROC krive (AUC) od 0,96 (95% CI 0,94-0,97) u odnosu na CRS. Pokazao je zbirnu osjetljivost od 93% (95% CI 88-96), specifičnost od 77% (95% CI 64-86) i AUC od 0,94 (95% CI 0,92-0,96) prema kulturi. Objedinjena osjetljivost, specifičnost i AUC MPB64 LAMP bili su 86% (95% CI 86-86), 100% (95% CI 100-100) i 0,97 (95% CI 0,95-0,98), respektivno, a oni za AMP IS6175% LAMP IS6175% su bili 4-1710% LAMP. 99% (95% CI 90-100) i 0,91 (95% CI 0,88-0,93), respektivno, u poređenju sa CRS.

Zaključci Ovi rezultati ukazuju na dobru dijagnostičku efikasnost LAMP-a u detekciji EPTB. Dodatno, dijagnostička efikasnost MPB64 LAMP-e bila je superiornija u odnosu na IS6110 LAMP-u.

Prikaži originalni naslov i sažetak na engleskom

Diagnostic accuracy of the loop-mediated isothermal amplification assay for extrapulmonary tuberculosis: A meta-analysis.

Background Loop-mediated isothermal amplification (LAMP) is used to detect pulmonary tuberculosis (PTB); however, the diagnostic accuracy of the LAMP assay for extrapulmonary tuberculosis (EPTB) is unclear. We performed a meta-analysis to evaluate the performance of LAMP in the detection of EPTB.

Methods We searched PubMed, EMBASE, the Cochrane Library, China National Knowledge Infrastructure (CNKI), and the Wanfang database for studies published before Sep 16, 2017. We reviewed studies and compared the performance of LAMP with that of a composite reference standard (CRS) and culture for clinically suspected EPTB. We used a bivariate random-effects model to perform meta-analyses and used meta-regression and subgroup analysis to analyze sources of heterogeneity.

Results Fourteen articles including 24 independent studies (16 compared LAMP to CRS, 8 to culture) of EPTB were identified. LAMP showed a pooled sensitivity of 77% (95% confidence interval (CI) 68-85), specificity of 99% (95% CI 96-100), and area under SROC curves (AUC) of 0.96 (95% CI 0.94-0.97) against CRS. It showed a pooled sensitivity of 93% (95% CI 88-96), specificity of 77% (95% CI 64-86), and AUC of 0.94 (95% CI 0.92-0.96) against culture. The pooled sensitivity, specificity, and AUC of MPB64 LAMP were 86% (95% CI 86-86), 100% (95% CI 100-100), and 0.97 (95% CI 0.95-0.98), respectively, and those of IS6110 LAMP were 75% (95% CI 64-84), 99% (95% CI 90-100), and 0.91 (95% CI 0.88-0.93), respectively, compared with CRS.

Conclusions These results suggest good diagnostic efficacy of LAMP in the detection of EPTB. Additionally, the diagnostic efficacy of MPB64 LAMP was superior to that of IS6110 LAMP.

Autorstvo i publikacija

Autori

Yu G, Shen Y, Zhong F, Ye B, Yang J, Chen G.

Časopis
PloS one
Vrste publikacije
Meta-analiza, Istraživačka podrška vlade izvan SAD-a, Istraživački članak, Članak u časopisu
Licenca
CC BY
Citiranja u Europe PMC
32
Provjerljivi identifikatori

Izvorni podaci

DOI
10.1371/journal.pone.0199290
PMID
29944682
PMCID
PMC6019099
Provjereno
2026-07-26
Otvori cijeli rad u Europe PMC
Napomena o bosanskom prijevodu

Naslov i sažetak prevedeni su automatski i prijevod može sadržavati netačnosti ili neprecizne stručne izraze. Za sve detalje, citiranje i medicinsko tumačenje pregledajte originalnu englesku verziju članka. Ne donosite zdravstvene odluke samo na osnovu ovog prijevoda.

Pregledaj originalni članak na engleskom